Guide
Choosing glove length: 245 to 600 mm
Glove length decides how much of the forearm and arm is protected, and how well the glove overlaps the garment sleeve. Longer is not always better: choose the length the task and the cleanroom grade need.
Lengths at a glance
- 245 mm: laboratory and general handling.
- 300 mm: standard cleanroom work, covering the wrist and lower forearm.
- 400 mm: extended cuff that overlaps the coverall sleeve.
- 480 mm: elbow length for aseptic interventions.
- 600 mm: shoulder length for Grade A/B work and isolators, where the arm reaches into the critical zone.
Try the interactive Liberty glove length guide or see the full glove range.
EU GMP Annex 1
The correct gowning order for Grade A/B
Gowning protects the product from the operator. The order matters: each step should cover what could contaminate the next, and nothing clean should touch anything dirty.
- Hand hygiene, then enter the changing room.
- Hood over hair, beard and neck.
- Mask and goggles, so the face and eyes are covered.
- Coverall, stepped into without the outside touching the floor.
- Overboots over the coverall legs, across the step-over bench.
- Sterile gloves over the sleeves; many sites double-glove.
- Check the full gown in the mirror before entering.
This is a typical sequence. Always follow your site's approved and qualified gowning procedure.
Know-how
Sterile or non-sterile wipes: when it matters
In Grade A and B areas, EU GMP Annex 1 expects disinfectants and detergents to be sterile before use, and the materials used with them must not add contamination. That is why sterile, multi-bagged wipes are used in the aseptic core.
In Grade C and D support areas, low-linting non-sterile wipes are often enough, as defined in the site's cleaning programme. The right choice depends on the grade, the surface and your validated cleaning procedure.
See Wipar sterile wipes and Wizz non-sterile wipes.